What was found
TWO AREAS OF DELAMINATED ON T/E WEDGE INNER 3" X 5" BY 1.75 X 3" MUST REPAIR AS 1 DUE TO PROXIMITY OF DAMAGES ONLY 4" APART. REPAIR REF SRM 57-53-01-2R-1, AND SRM 51-70-17.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TWO AREAS OF DELAMINATED ON T/E WEDGE INNER 3" X 5" BY 1.75 X 3" MUST REPAIR AS 1 DUE TO PROXIMITY OF DAMAGES ONLY 4" APART. REPAIR REF SRM 57-53-01-2R-1, AND SRM 51-70-17.