What was found
INSPECTION TYPE: D, MAIN DECK BS 860-980, LBL 11-33, FLOOR PANEL FOUND CRACK AND BROKEN. FLOOR PANEL FABRICATED IAW DWG 65B23341-29 AND INSTALLED IAW AMM 53-21-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
INSPECTION TYPE: D, MAIN DECK BS 860-980, LBL 11-33, FLOOR PANEL FOUND CRACK AND BROKEN. FLOOR PANEL FABRICATED IAW DWG 65B23341-29 AND INSTALLED IAW AMM 53-21-02.