What was found
INSPECTION TYPE:4C, APPROX .50" CRACK ALONG AFT EDGE OF INTERCOSTAL PN AJC7582-5 AT TYPICAL LOCATION IN RADIUS OF RELIEF CUT OUT FOR VERT STAB AFT SPAR. REPAIRED INTERCOSTAL (PN AJ7582-5) AT VERT STAB AFT SPAR RELIEF CUT OUT REF SRM 55-30-01, FIG 201 REPAIR 2, STASA EA 011- 5530-01-A4557 REV I/R, EO MD11-5530-50324-A.