What was found
DURING FLIGHT, POS 1 STARTER GEN FAILED. CHECKLIST FOR SINGLE GEN FAILURE WAS PERFORMED & NO INDICATION OF GEN OUTPUT WAS NOTED. PIC DIVERTED FLIGHT FOR LANDING AT A CLOSER AIRPORT. DURING APPROACH FOR LANDING POS 1 ENG BEGAN TO LOSE POWER. ALL POWER ON POS 1 ENG WAS LOST DURING A 1 MINUTE INTERVAL. DUE TO THE FACT THAT THE ENG LOST THRUST, TEMP INDICATION & LOW TO NO N1 INDICATION, THE PIC SUSPECTED FLAMEOUT OCCURRED. ACFT CONTINUED FLIGHT & EXECUTED LANDING WITHOUT INCIDENT WITH ONE ENG OPERATING. ACFT IS UNDERGOING INSPECTION & MX TO DETERMINE CAUSE OF LOSS OF ENG. THE STARTER GEN TIME IN SERVICE SINCE OVERHAUL WAS 849 HOURS, 610 CYCLES & 21M 12D.