What was found
DURING ROUTINE C-CHECK INSPECTION EVIDENCE OF LIGHTNING STRIKES WERE DETECTED ON FUSELAGE STATION 180 LONGERONS 9R. REPAIR ACCOMPLISHED REMOVAL OF DAMAGED AREA FABRICATION AND INSTALLATION OF REPAIR DOUBLER IN ACCORDANCE WITH DOUGLAS STRUCTURAL MANUAL AND DRAWING R-74-R01.