Service difficulty report · Control Cable · Doug DC871F

Difficulty date
March 5, 2003
Submitted
March 10, 2003
Operation
Air carrier
Aircraft
N820BX
Make and model
Doug DC871F
Aircraft serial
46065
Aircraft time
82,687 hours, 34,421 cycles
System (JASC)
7603 · Power Lever
Part
Control Cable
Condition
Out Of Rig
Location
Nr 1 Engine
Part time
82,687 hours, 34,421 cycles
Stage of operation
CR
How discovered
V
Nature of condition
O
Precautionary procedure
E

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

AFTER DEPARTURE FROM GSO WHILE PERFORMING POST HEAVY MAINTENANCE CHECK FLIGHT. COMPRESSOR STALL ON NR 1 ENGINE WAS NOTED WHILE REDUCING POWER SETTING FROM CLIMB TO CRUISE. AS PRECAUTIONARY ACTION NR 1 ENGINE WAS SHUTDOWN. AS MORE INFORMATION BECOMES AVAILABLE IT WILL BE PROVIDED. MAINTENANCE INSPECTED FAN EXHAUST AND BOROSCOPED ENGINE IN ACCORDANCE WITH CFM56 MAINTENANCE MANUAL AND ATI JOB CARD 30.07. MAINTENANCE FOUND VARIABLE STATOR VALVE AND VARIABLE BLEED VALVE FEEDBACK CABLE OUT OF RIG. MAINTENANCE RIGGED CABLES IN ACCORDANCE WITH CFM56 MAINTENANCE MANUAL.

More about the Doug DC-8-71F