What was found
DURING A ROUTINE C-CHECK INSPECTION RIGHT INBOARD FLAP UPPER PANEL DOUBLER HAS WEAR OUT OF LIMITS STA XW.104.000-110.000 MAJOR REPAIR. MAINTENANCE PERFORMED MAJOR REPAIR IN ACCORDANCE WITH DC8 STRUCTURAL REPAIR MANUAL 51-1-21A PG 1-4. FABRICATED NEW PLATING (2024T30.040") IN ACCORDANCE WITH 57-7-1 PG 2. CLEANED, TREATED AND PRIMED AREA AND INNER FACE OF PLATING IN ACCORDANCE WITH DC8 STRUCTURAL REPAIR MANUAL 57-7-1 PG 2, DC8 STRUCTURAL REPAIR MANUAL 51-1-21A PG 1-4, DC8 STRUCTURAL REPAIR MANUAL 51-3-0 PG 1.