What was found
DURING A ROUTINE C CHECK INSPECTION, FOUND FWD ACCY COMPT FRAME CRACKED 1" AT STA 55.000, 1-24R. REPAIRS WERE ACCOMPLISHED BY PERFORMING MAJOR REPAIRS IAW DC8 SRM 53-2-0 FIG 2. REMOVED FASTENERS IAW DC8 SRM 51-1-21 PAGES 1, 2. REMOVED DAMAGED FRAME IAW DC8 SRM AND ANGLE DOUBLERS IAW DC8 SRM 53-2-0 FIG 2 PAGE 1 OF 3. PERFORMED HEAT TREATMENT IAW DC8 SRM 51-1-1 PAGES 1-13-17. CLEANED, TREATED AND PRIMED AREA AND FRAME SEGMENT AND ANGLES IAW DC9 SRM 51-1-8B. APPLIED PRC SEALANT TO FAYING SURFACES AND INSTALLED FRAME SEGMENT AND ANGLE DOUBLERS WITH NEW FASTENERS IAW DC9 SRM 53-2-0 FIG 2, DC8 SRM 51-1-21 PAGE 1, DC8 SRM 51-1-20D, PAGE 9 DC8 SRM 51-1-15 PAGE 1.