What was found
DURING A ROUTINE C-CHECK INSPECTION FOUND RT FUSELAGE AFT CENTER SECTION LOWER PLATING OLD OMEGA ANTENNA DOUBLER MISSING ON ROW FASTENERS AND MAX PITCH EXCEEDS LIMITS AT STA FS 1322.00L, 35.5R. MAJOR REPAIR ACCOMPLISHED REMOVAL OF EXISTING REPAIR. REMOVED DAMAGED AREA. PERFORMED NDT INSPECTION TO AREA. FABRICATED REPAIR DOUBLER AND INTERNAL FINGER DOUBLERS AND FILLER. CLEANED, TREATED AND PRIMED AREA AND REPAIR PARTS. APPLIED SEALANT TO FAYING SURFACES. INSTALLED REPAIRED PARTS IAW DC8 SRM 3-2-1 FIG 7, FIG 1 AND 3, 53-2-0, 53-4-1 FIG 16 SH 1, 51-10-1 FIG 2 SH 5, 51-3-1, 51-3-5, 51-1-4, 51-1-20D, 51-1-21.