What was found
DURING ROUTINE C-CHECK FOUND ANGLE CORRODED AT STATION 297 LONGERON 29 LEFT. REMOVED ANGLE, FABRICATED NEW ANGLE, LOCATED, DRILLED, TREATED, PRIMED, AND INSTALLED NEW ANGLE WITH NEW HI-LOKS AND RIVETS IAW DC8 SRM 51-1-21, 51-1-4, 51-1-5, AND 51-1-8.