What was found
DURING INSPECTION CHECK, FOUND A CRACK ON TOP PANEL PLATING AT CENTER SPAR AND STA XRS 74.869 LT. DAMAGE WILL BE REPAIRED IAW EWO ATI 57-040 AND SRM 57-2-1 FIG 17.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING INSPECTION CHECK, FOUND A CRACK ON TOP PANEL PLATING AT CENTER SPAR AND STA XRS 74.869 LT. DAMAGE WILL BE REPAIRED IAW EWO ATI 57-040 AND SRM 57-2-1 FIG 17.