What was found
DURING INSPECTION CHECK,CORROSION WAS FOUND ON STABILIZER UPPER TRAILING EDGE PLATING STA XE 28-RH. REPAIR ACCOMPLISHED, REMOVAL PANEL AND STIFFENER, FABRICATION AND INSTALLATION NEW PANEL AND STIFFENER IAW DRAWINGS 55-05467-1, 55-05467-2, 55-05467-3, 55-05467-4 AND EWO ATI-55-010.