What was found
DURING INSPECTION CHECK, FOUND CORROSION ON HORIZONTAL STABILIZER TRAILING EDGE LOWER AND UPPER PANEL. REPAIR ACCOMPLISHED, REMOVED PANEL AND STIFFENER, FABRICATED AND INSTALLED NEW PANEL AND STIFFENER IN ACCORDANCE WITH DRAWINGS 55-05467-1, 55-05467-2, 55-05467-3, 55-05467-4 AND EWO ATI-55-010.