What was found
DURING ROUTINE C-CHECK INSPECTION, FWD CARGO COMPT INTERIOR. SPLICE FITTING CRACKED, STA 600.00 - STA 620.000, L-31R. REMOVED CRACKED FITTING IAW DC-8 SRM 51-1-20D PAGE 21. FABRICATED NEW FITTING (ALCLAD 7075 T6 51) IAW DWG 3750257. PERFORMED NDT INSPECTION TO FITTING IAW NDT SPM PART 08-00-02/07. CLEANED, TREATED AND PRIMED AREA + NEW FITTING IAW DC-8 SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW DC-8 SRM 51-1-11 PAGE 9. INSTALLED NEW FITTING IAW DC-8 SRM 51-1-20D PAGE 9. TORQUED IAW DC-8 SRM 51-3-1.