What was found
DURING ROUTINE C CHECK INSPECTION, MAIN CARGO CMPT. FITTING CORRODED AT STA. 1690.00, L-36 REMOVED CORROSION IAW SRM 51-1-8 PAGES 17-18. FOUND OUT OF LIMITS IAW SRM 53-2-0 PAGE 21. REMOVED CORRODED FITTING IAW SRM 51-1-20D PAGE 21. FABRICATED NEW FITTING IAW DWG NR 4641324 (ALCLAD 7075 T6 51). PERFORMED HEAT TREATMENT IAW SRM 51-1-11 PAGES 1,13,17. PERFORMED NDT INSPECTION IAW NDT SPM PART 08-00-02 TO 07. CLEANED, TREATED AND PRIMED AREA + NEW FITTING IAW SRM 51-1-8B. INSTALLED NEW FITTING IAW SRM 51-1-20D PAGE 9. TORQUED IAW SRM 51-3-1.