What was found
DURING ROUTINE C CHECK INSPECTION, RT WING. CTR L/E SKIN FWD PART HAS NON STANDARD REPAIR. PERFORMED MAJOR REPAIR IAW SRM 57-1-0 PAGE 1, SRM 57-3-1 FIG. 5 SHEET 1, EO SEMAN NR 2005910 DATE 06-18-05. REMOVED DAMAGED PLATING WITH INTERIM REPAIR IAW SRM 51-1-21 PAGE 1. FABRICATED NEW PLATING (ALCLAD 7075 T6 0.063”) IAW SRM 57-3-1 FIG. 5 SHEET 1 ITEM (G). CLEANED, TREATED AND PRIMED AREA AND NEW PLATING INTERNAL PART IAW SRM 51-1-8B. APPLIED PRC SEALANT TO FAYING SURFACES IAW SRM 51-1-11 PAGE 1. INSTALLED NEW PLATING IAW SRM 51-1-21 PAGE 1, SRM 51-3-0 PAGE 1, SRM 51-1-20D. TORQUED IAW SRM 51-3-1.