What was found
DURING ROUTINE C CHECK INSPECTION, RT IB AIL L/E UPPER PLATING CRACK .2500 AT STA XA 470.000. PERFORMED MAJOR REPAIR IAW SRM 57-8-1 FIG 1, EO SEMAN NR 20051280 DATED 09-26-05. REMOVED DAMAGED PLATING IAW SRM 51-1-21. FABRICATED NEW PLATING (AL2024T3 0.040) IAW SRM 57-8-1 FIG 1 ITEM E, SRM 51-1-4 PG 1 (FORMING). CLEANED,TREATED, PRIMED AREA + INNER FACE OF NEW PLATING IAW SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACE IAW SRM 51-1-11 PG 9. INSTALLED NEW PLATING IAW SRM 51-1-21.