What was found
DURING C CHECK INSPECT, LT FUSELAGE NOSE SECTION PLATING DOUBLER REPAIR EXCEED MAX RIVETS SPACING STA FS 10 L-22 LT. PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3 # 05448 DATED 10-05-05, SEMAN DWG # ED 4076 DATED 10-03-05, EO SEMAN # 20051294 DATED 10-05-05. REMOVED EXISTING REPAIR DOUBLER IAW DC8 SRM 51-1-21 PG 1, DC8 SRM51-1-20D. REMOVED DAMAGED SECTION IAW SEMAN DWG # ED-4076. NDT INSPECTED REWORKED AREA IAW DC8 NDT SPM PART 06-10-01-001. NO CRACK NOR CORROSION FOUND. FABRICATED REPAIR DOUBLER (AL7075T6 0.071”, FINGER DOUBLER (AL7075T6 0.032”) IAW SEMAN DWG # ED-4076. CLEANED, TREATED, PRIMED AREA, REPAIR PARTS IAW DC8 SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW DC8 SRM 51-1-11 PG 9. INSTALLED R