What was found
DURING C-CHECK INSPECT, RT FUSE FWD CTR SECTION LWR PLATING FWD OF A PIT DOOR EXISTING DBLR EXCEED MAX RIVETS SPACING AT BS 272.00 L-31R. PERFORMED MAJOR REPAIR IAW FORM 8110-3 NR 05451, SEMAN DWG NR ED-4078, EO SEMAN 20051296. REMOVED REPAIR DOUBLER IAW DC8 SRM 51-1-21, DC8 SRM 51-1-20D. REMOVED DAMAGED SECTION IAW SEMAN DWG ED-4078. NDT INSPECTED REWORKED AREA IAW DC8 NDT SPM. NEITHER CRACK NOR CORROSION FOUND. FAB`D REPAIR DOUBLER & REPAIR TRIPLER & FILLER INTERNAL DOUBLER & FILLER IAW SEMAN DWG ED-4078. CLEANED, TREATED, PRIMED AREA & REPAIR PARTS IAW DC8 SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW DC8 SRM. INSTALLED REPAIR PARTS IAW SEMAN DWG ED-4078, DC8 SRM 51-1-20D, DC8 SRM 51-3-1.