What was found
DURING C CHECK INSPECT, RT FUSELAGE AFT CENTER SECTION FWD OF R-2 DOOR OPENING EVALUATE CONFORMITY PER SRM AT STA FS 1550.00 L-15.5 RT. PERFORMED MAJOR REPAIR IAW DC8 SRM 53-2-0 FIG 22A, EO SEMAN NR 20051300 DATED 09-28-05. REMOVED EXISTING REPAIR DOUBLER IAW DC8 SRM 51-1-21. FABRICATED REPAIR DOUBLER ( -7073) (AL7075T6 0.190”) IAW DC8 SRM 53-2-0 FIG 22A (SHEET 1, 3, 14), DC8 SRM 53-4-1 FIG 19 ITEM “B”. CLEANED, TREATED, PRIMED AREA + REPAIR DOUBLER IAW DC8 SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW DC8 SRM 51-1-11 PG 9. INSTALLED REPAIR DOUBLER IAW DC8 SRM 53-2-0 FIG2A (SHEET 3, 12, 13, 14), DC8 SRM 51-1-21, DC8 SRM 51-1-20D, DC8 SRM 51-3-1 (TORQUE).