What was found
DURING C CHECK INSPECTION, EXT FS NON STANDARD REPAIR, STA 8.000 STA 17.000 BTWN L-15 AND L-16L. PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3 NR 05447 DATED 10-05-05, SEMAN DWG # ED-4077 DATED 10-01-05 AND EO SEMAN # 20051295 DATED 10-05-05. REMOVED EXISTING DOUBLER IAW DC8 SRM 51-1-21, DC8 SRM 51-3-0. REMOVED DAMAGED AREA IAW SEMAN DWG # ED-4097. PERFORMED NDT INSPECT ON AFFECTED AREA IAW DC8 NDT SPM PART 06-10-01-001. NO CORROSION NEITHER CRACK FOUND. FAB`D REPAIR DOUBLER (AL7075T6 0.071), 02 INTERNAL FINGER DOUBLERS (AL7075T6 0.032), FILLER (AL7075T6 0.050) IAW SEMAN DWG NR ED-4077. CLEANED, TREATED, PRIMED AREA + REPAIR PARTS IAW DC8 SRM 51-1-8B. APPLIED PRC SEALANT TO FAYING SURFACES IAW DC8 SRM 51-1-