What was found
DURING C-CHECK, RT WING - L/E SLOT VANE HAS NON STANDARD REPAIR, XOLDO 66. PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3 05586 DATED 12-28-05, SEMAN DWG ED-4136 DATED 12-23-05, ED SEMAN 2005 1473 DATED 12-28-05. REMOVED NON STANDARD REPAIR. REMOVED DAMAGED SECTION, PERFORMED NDT INSP IAW DC8 NDT SPM PART 06-10-01-001, FABRICATED REPAIR DOUBLER (AL 7075 T6 0.071) & FILLER, INTERNAL DOUBLER (ALCLAD 7075 T6 0.063) IAW SEMAN DWG ED-4136. CLEANED, TREATED; PRIMED AREA & INNER FACE OF REPAIR PARTS IAW DC8 SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW DC8 SRM 51-1-11, INSTALLED REPAIR PARTS IAW SEMAN DWG ED-4136, DC8 SRM 51-1-21, DC8 SRM 51-1-20D, DC-8 SRM 51-3-0, DC8 SRM 51-3-1 (TORQUE).