What was found
DURING ROUTINE C-CHECK INSPECTION, MAIN CARGO CMPT - WING CENTER SECTION FITTING CRACKED 3, AT STA 822.500, L-22R. REMOVED CRACKED FITTING IAW DC-8 SRM 51-1-20D. FABRICATED NEW FITTING IAW ATI REPAIR SPECIFICATION 2003-05, DOUGLAS DWG 4753360. PERFORMED NDT INSP IAW DC-8 NDT SPM PART 08-00-02-07. CLEANED, TREATED AND PRIMED AREA & NEW FITTING IAW DC-8 SRM 51-1-8B. INSTALLED NEW FITTING IAW DC-8 SRM 51-1-20D, DC-8 SRM 51-3-1.