What was found
DURING ROUTINE C-CHECK INSPECTION, AFT CARGO COMPARTMENT CORROSION ON LONGERON 36 BETWEEN STA FS 1380.000 AND 1420.000. PERFORMED BLEND OUT 0.015, MATERIAL THICKNESS 0.150, REMAINING MATERIAL 0.135 ON LWR RADIO AREA AND BLEND OUT 0.011, MATERIAL THICKNESS 0.135, REMAINING MATERIAL 0.124 ON LONGITUDINAL HORIZONTAL LWR AREA FOUND WITHIN ALLOWABLE LIMITS IAW DC-8 SRM 53-2-0 FIG IF SHEET 3 PAGE 2P. APPLIED ALODINE AND REPAINTED AREA IAW DC-8 SRM 51-1-8B.