What was found
DURING C CHECK INSPECT, MLG W/W FRAME FITTING CORRODED, STA 960.000 L-24. PERFORMED MAJOR REPAIR IAW DC-8 SRM 53-1-0 PG 1, DC-8 SRM 53-2-0 FIG. 8 (SHEET 1), EO SEMAN # 2005845 DATE 06-27-05. REMOVED CORROSION IAW DC-8 SRM 51-1-8 PG 17, 18, FOUND OUT OF LIMITS IAW DC-8 SRM 53-2-0 FIG 1F (SHEET 3) PAGE 2P. REMOVED CORRODED FRAME FITTING IAW DC-8 SRM 51-1-20D PG 21. FAB`D FRAME FITTING (NEW) (ALCLAD 7075 T6 51) IAW DWG DOUGLAS NR 3647117, EO SEMAN # 2005842. PERFORMED HEAT TREATMENT IAW DC-8 SRM 51-1-1 PG 1, 13, 17. PERFORMED NDT INSPECT IAW DC-8 SPM PART 08-00-02 TO 07. CLEANED, TREATED AND PRIMED AREA, NEW FRAME FITTING IAW DC-8 SRM 51-1-8B. TRIMMED OUT NEW FITTING TO INSTALL IAW DC-8 SRM 53-2-0 FIG 8 (SHEE