What was found
DURING ROUTINE C CHECK INSPECTION, MLG W/W FITTING FRAME CORRODED, STA 879.375 AND L-24. PERFORMED MAJOR REPAIR IAW DC-8 SRM 53-2-0 FIG. 8, EO SEMAN NR 2005843 DATE 06-23-05. REMOVED CORROSION IAW DC-8 SRM 51-1-8 PAGES 17, 18. FOUND OUT OF LIMITS IAW DC-8 SRM 53-2-0 PAGE 2P. REMOVED CORRODED FITTING IAW DC-8 SRM 51-1-20D PAGE 21. FABRICATED SPLICES (02 EA) (ALCLAD 7075 T7 351), (02 EA) SHIMS (ALCLAD 7075 T6 0.071”) IAW DC-8 SRM 53-2-0 FIG 8 (SHEET 1, 3, 6). CLEANED, TREATED AND PRIMED AREA + REPAIR PARTS IAW DC-8 SRM 51-1-8B. INSTALLED NEW FRAME FITTING (PN 3641 00 4 U 504) + NEW DOUBLER (PN 5802677-7N) + (04 EA) SPLICES + (06 EA) SHIMS IAW DC-8 SRM 53-2-0 FIG 8 SHEET 1, 3, 6, DC-8 SRM 51-1-20D PAGE 9.