What was found
DURING C CHECK INSPECT, MLG W/W L-24 CRACKED 2", STA 980.000. PERFORMED MAJOR REPAIR IAW DC-8 SRM 53-2-2 FIG 5 TR NR 53-123 DATE 05-15-01, EO SEMAN NR 2005831 DATE 06-16-05. REMOVED FASTENERS IAW DC-8 SRM 51-1-20D PAGE 21. PERFORMED SLOP HOLE ON CRACK END IAW DC-8 SRM 53-2-2 FIG 5 SHEET 21. PERFORMED NDT INSPECT IAW DC-8 NDT SPM PART 06-10-01-001. NO CRACK, CORROSION FOUND. FAB`D REPAIR ANGLE (ALCLAD 2024 T3 0.125”) + WASHERS (ALCLAD 2024 T3 0.090) IAW DC-8 SRM 53-2-2 FIG 5 SHEET 24 IAW DC-8 SRM 51-1-4 PAGE 1. CLEANED, TREATED AND PRIMED AREA + REPAIR PARTS IAW DC-8 SRM 51-1-8B. APPLIED PRC SEALANT TO FAYING SURFACES IAW DC-8 SRM 51-1-11 PAGE 9. INSTALLED REPAIR PARTS IAW DC-8 SRM 53-2-2 FIG 5 SHEET 21, 24,