What was found
DURING ROUTINE C CHECK, FOUND RIGHT WING UPPER SKIN CRACKED AT STATION XFS 132.250. REMOVED FASTENERS AS NEEDED TO PERFORMED REPAIR. REMOVED DAMAGE. FABRICATED DOUBLER AND FILLER, LOCATED, DRILLED, TRIMMED, TREATED, PRIMED, INSTALLED DOUBLER, FILLER AND NEW FASTENERS WET WITH SEALANT FROM STATION XFS 116.250 TO 132.250 AT FRONT SPAR IAW COOPESA E.O. COO-8-57-384-04 DATED 10/12/2004.