What was found
DURING ROUTINE C CHECK, FOUND RIGHT WING OUT BOARD FLAP DENTED AT STATION XW384. REMOVED FASTENERS AS NEEDED. REMOVED DAMAGE. FABRICATED REPAIR PARTS, LOCATED, DRILLED TRIMMED, TREATED, PRIMED, INSTALLED NEW REPAIR PARTS AND NEW FASTENESR WET WITH SEALANT FROM STATION WX382 TO STATION XW385 IAW DC8 SRM 57-2-5, 51-1-5, AND 51-1-8.