What was found
DURING ROUTINE C-CHECK FOUND LT WING IB TRAILING EDGE FLAP LOWER SURFACE DENTED OUT OF LIMITS AT STATION XW39 AFT AREA. REMOVED DAMAGE. FABRICATED FILLER AND DOUBLER. LOCATED, DRILLED, TRIMMED, TREATED, PRIMED, AND INSTALLED FILLER AND DOUBLER WET WITH SEALANT FROM STATION XW34 TO STATION XW44. IAW SRM 57-2-5, 51-1-5, AND 51-1-8.