What was found
DURING ROUTINE C-CHECK FOUND LT WING IB TRAILING EDGE FLAP UPPER SURFACE DENTED OUT OF LIMITS AT STATION XW35. REMOVED DAMAGE, FABRICATED FILLER AND DOUBLER. LOCATED, DRILLED, TRIMMED, TREATED, PRIMED, AND INSTALLED FILLER AND DOUBLER WET WITH SEALANT FROM STATION XW32 TO STATION XW39. IAW SRM 57-2-5, 51-1-5, AND 51-1-8.