What was found
DURING ROUTINE C-CHECK FOUND LT HORIZONTAL STABILIZER LEADING EDGE DENTED AT STATION XFS 307.750. REMOVED DAMAGE. FABRICATED REPAIR PARTS, LOCATED, DRILLED, TRIMMED, TREATED, PRIMED, INSTALLED REPAIR PARTS, AND FASTENERS, WET WITH SEALANT FROM STATION XFS 300 TO STATION XFS 312 IAW SRM 55-2-1, 51-1-4, 51-1-5, AND 51-1-8.