What was found
DURING ROUTINE C-CHECK FOUND MAIN CARGO CABIN SUPPORT END FITTING CORRODED AT STATION Y55 -X65 Z0. REMOVED FASTENERS AS NEEDED TO REMOVE END FITTING. MANUFACTURED NEW END FITTING, LOCATED, DRILLED, TREATED, PRIMED, INSTALLED NEW END FITTING AND FASTENERS AT STATION Y55 -X65 Z0. IAW SRM 51-3-0, 51-1-20, 51-3-1, AND 51-1-8.