What was found
DURING ROUTINE C CHECK, FOUND EMERGENCY EXIT DOOR BEAM INBOARD CHORD CRACKED AT CENTER SECTION FROM STATION 1110.000 TO STATION 1140.000 AT STOP FITTING 7. REMOVED FASTENERS AS NEEDED TO REMOVE DAMAGED CHORD. FAB`D NEW CHORD, LOCATED, DRILLED, TRIMMED, TREATED, PRIMED, INSTALLED NEW CHORD AND FASTENERS FROM STATION 1110.000 TO STATION 1140.000 AT STOP FITTING 7 IAW DC8 SRM 52-1-0, 51-1-21, AND 51-1-8.