What was found
DURING ROUTINE C CHECK, FOUND LEFT HORIZONTAL STABILIZER INBOARD TRAILING EDGE LOWER ANGLE CRACKED AT STATION XE 29.77. REMOVED DAMAGE, FABRICATED REPAIR PART, LOCATED, DRILLED, TRIMMED, TREATED, PRIMED, INSTALLED REPAIR PART AND FASTENERS IN LEFT HORIZONTAL STABILIZER TRAILING EDGE LOWER ANGLE AT STATION XE 29.77 IAW DC8 SRM 51-2-1, 51-1-4, 51-1-5 AND 51-1-8.