What was found
DURING ROUTINE C CHECK, FOUND EXTERNAL FUSELAGE ANGLE CRACKED AT STATION 980 BETWEEN +X65 TO -Z54. REMOVED FASTENERS AS NEEDED TO REMOVE DAMAGED ANGLE. FABRICATED NEW ANGLE, LOCATED, DRILLED, TRIMMED, TREATED, PRIMED, INSTALLED NEW EXTERNAL FUSELAGE ANGLE AND FASTENERS AT STATION 980 BETWEEN +X65 AND -Z54 IAW 53-8-1, 51-1-4, 51-1-5, AND 51-1-8.