What was found
DURING ROUTINE C CHECK, FOUND RIGHT HAND OUTBOARD FLAP LEADING EDGE INBOARD HINGE AT FLAP STATION XRS-230.000 ICE DOOR INBOARD TRACK GOUGED. REMOVED FASTENERS AS NEEDED TO REMOVE DAMAGED TRACK. FABRICATED NEW TRACK, LOCATED, DRILLED, TRIMMED, DEBURRED, TREATED, PRIMED, INSTALLED NEW TRACK AND FASTENERS AT RIGHT HAND OUTBOARD FLAP LEADING EDGE INBOARD HINGE AT FLAP STATION XRS-230.000 ICE DOOR INBOARD TRACK IAW DC8 SRM 51-1-21, 51-1-8, 51-1-8B, 51-3-0, 51-1-4 AND 57-2-0.