What was found
DURING ROUTINE C CHECK, FOUND A CRACKED CUSP BETWEEN STATION 980 AND 1000 AT LONGERON 21 RIGHT. REMOVED DAMAGE, FABRICATED REPAIR DOUBLER, LOCATED, DRILLED, TRIMMED, DEBURRED, TREATED, PRIMED, INSTALLED REPAIR DOUBLER AT STATION 980 AND 1000 AT LONGERON 21 RIGHT IAW DC8 SRM 53-2-0, AND 51-1-8.