What was found
DURING ROUTINE C-CHECK FOUND WEB CRACKED APPROXIMATELY .5 INCH AT STATION 1906 LONGERON 30 LEFT. REMOVED DAMAGE. FABRICATED DOUBLER, LOCATED, DRILLED, TRIMMED, DEBURRED, TREATED, PRIMED, INSTALLED DOUBLER AND NEW FASTENERS AT STATION 1906 LONGERON 30 LEFT IAW DC8 SRM 53-5-0, 53-2-0, AND 51-1-8.