What was found
DURING ROUTINE C-CHECK FOUND WEB CRACKED APPROXIMATELY .5 INCH AT STATION 1910 LONGERON 30 RIGHT. REMOVED DAMAGE. FABRICATED DOUBLER, LOCATED, DRILLED, TRIMMED, DEBURRED, TREATED, PRIMED, INSTALLED DOUBLER AND NEW FASTENERS AT STATION 1910 LONGERON 30 RIGHT IAW DC8 SRM 53-5-0, 53-2-0, AND 51-1-8.