What was found
DURING ROUTINE C CHECK, FOUND THE LEFT NR 4 FLAP VANE CENTER OUTBOARD FLAP ATTACH PLATE GOUGED. REMOVED DAMAGED PLATE, FABRICATED NEW PLATE, LOCATED, DRILLED, TRIMMED, TREATED, PRIMED AND INSTALLED NEW PLATE IAW DOUGLAS DRAWING 565-37552 DC8 SRM 51-3-0, AND 51-1-8.