What was found
DURING ROUTINE C CHECK, FOUND LEFT MAIN LANDING GREA STRUT CUTOUT AFT VERTICAL WEB GOUGED. FABRICATED REPAIR PARTS, LOCATED, DRILLED, TRIMMED, TREATED, PRIMED, AND INSTALLED NEW REPAIR PARTS IAW DC8 SRM 51-1-21, 51-1-8, AND DOUGLAS DRAWING 5651221.