What was found
DURING ROUTINE C CHECK, FOUND RIGHT INBOARD FLAP INTERNAL WEB CRACKED AT INBOARD LEADING EDGE AT STATION XF1. FABRICATED REPAIR PARTS, LOCATED, DRILLED, TRIMMED, TREATED, PRIMED, AND INSTALLED NEW REPAIR PARTS IAW DC8 SRM 57-20-0, 51-1-8, AND 51-1-21.