What was found
DURING ROUTINE C CHECK FOUND IMPROPER REPAIR AT STATION 8.00 LONGERON 33 LT. REMOVED EXISTING REPAIR. FABRICATED NEW REPAIR PARTS, LOCATED, DRILLED, TRIMMED, TREATED, PRIMED, AND INSTALLED NEW REPAIR PARTS. IAW TAMPA ENGINEERING WORK ORDER EWO ATI 53-052 DATED APRIL 14,2006.