What was found
DURING ROUTINE C-CHECK INSPECTION, FWD CARGO COMPT STRUCTURE UNDER CROSS-SLIDE DOOR -B- HAS CRACKED FITTING STA 540.000 BETWEEN L-26L AND L-27L. REMOVED CRACKED FITTING IAW DC-8 SRM 51-1-20D. CLEANED, TREATED AND PRIMED AREA IAW DC-8 SRM 51-1-8B. INSTALLED NEW FITTING IAW DC-8 SRM 51-1-21, DC-8 SRM 51-1-20D, DC-8 SRM 51-3-1 (TORQUE).