What was found
DURING ROUTINE C CHECK INSPECTION, ON RIGHT OUTBOARD FLAP, A SMALL DENT WAS FOUND ON UPPER SKIN AT STA XF 217, DUE TIME CHANGE. PERFORMED MAJOR REPAIR IAW DC8 SRM 57-7-1 FIG 4, TR 57-94, EO SEMAN 20051460 DATED 12-16-05. REMOVED DAMAGED PLATING IAW DC8 SRM 57-1-0, DC8 SRM 51-1-21. FABRICATED NEW PLATING IAW DC8 SRM 57-7-1 FIG 4, TR 57-94 ITEM C DATED 10-01-02. CLEANED, TREATED AND PRIMED INNER FACE OF NEW PLATING IAW DC8 SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACE IAW DC8SRM 51-1-11 PG 9. INSTALLED NEW PLATING IAW DC8 SRM 51-1-21.