What was found
DURING ROUTINE C CHECK INSPECTION, MAIR CARGO MPT - NR 1 TRACK ATTACH FITTING CRACKED + FLOOR SUPPORT ANGLE CRACKED STA 1580.000 LBL.60. REMOVED CRACKED FITTING IAW SRM 51-3-0. FABRICATED NEW FITTING (ALCLAD 7075 T6 51) IAW ATI REPAIR SPECIFICATION NR 2005-05, DWG NR 5772399. PERFORMED HEAT TREAMENT IAW SRM 51-1-1 PAGES 1,13,17. PERFORMED NON DESTRUCTIVE INSPECTION IAW NDT SPM PART 08-00-02 TO 07. CLEANED, TREATED AND PRIMED AREA + NEW FITTING IAW SRM 51-1-8B. INSTALLED NEW FITTING IAW SRM 51-3-0, DC-8 SRM 51-3-1 (TORQUED) THE FLOOR SUPPORT ANGLE IS NOT CRACKED BY EDDY CURRENT INSPECTION.