What was found
DURING C CHECK, INSTALLATION OF DOUBLER ON FS 188.000 L-1 TO L-2R REQUIRED DUE TO SEXTANT EQUIPMENT REMOVAL. PERFORMED MAJOR REPAIR IAW FAA FORM 8110-3 NR 06029 DATED 01-23-06, SEMAN DWG ED-4167 DATE 01-21-06, EO SEMAN # 2006100 DATE 01-23-06. REMOVED EXISTING SPACER, REMOVED DAMAGED AREA IAW SEMAN DWG ED-4167. PERFORMED NDT INSPECTION IAW DC8 NDT SPM PART 06-10-01-001. FAB`D REPAIR DOUBLER, REPAIR TRIPLER, FILLER SKIN, FILLER INTERNAL DOUBLER IAW SEMAN DWG ED-4167. CLEANED, TREATED AND PRIMED AREA, REPAIR PARTS IAW DC8 SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW DC8 SRM 51-1-11. INSTALLED REPAIR PARTS IAW SEMAN DWG ED-4167, DC8 SRM 51-1-20D, DC8 SRM 51-3-1 (TORQUED).