What was found
DURING ROUTINE C-CHECK INSPECTION, EO 25-DC8-520 R4 PARTITION UPPER ATTACHMENT RELOCATION TO FS-STC00171 LA-D. PERFORMED ALTERATION MAJOR IAW FAA FORM 8110-3 DATE 10-04-05. EO 25-DC-8-520 REV STATES 4 DATES 11-11-2005, ATI DWG C40-MO2 REV C DATE 10-04-05. FABRICATED DOUBLERS, STRAPS IAW ATI DWG C40-MO2. PERFORMED HEAT TREATMENT TO FITTING IAW DC-8 SRM 51-1-1 PAGES 1, 13, 17. CLEANED, TREATED AND PRIMED AREA & REPAIR PARTS. APPLIED SEALANT TO FAYING SURFACES. INSTALLED REPAIR PART.