What was found
DURING ROUTINE C-CHECK INSPECTION, LT WING FLAP L/E INBOARD PANEL LWR PART DENTED 3 INCHES, STA XW 79.000. PERFORMED MAJOR REPAIR IAW DC8 SRM 57-7-1 FIG 1. REMOVED DAMAGED PANEL PLATING IAW DC8 SRM 57-1-0, DC8 SRM 51-1-21. FABRICATED PLATING (AL 2024T3 0.032) + BONDED FINGER DOUBLER (AL 2024T3 0.020) IAW DC8 SRM 57-7-1 FIG 1 ITEMS B, L. BONDED BOTH PARTS WITH HYSOL IAW DC8 SRM 51-1-9, DC8 SRM 51-1-9A. CLEANED, TREATED AND PRIMED AREA + NEW PANEL PLATING IAW DC8 SRM 51-1-8B. APPLIED SEALANT TO FAYING SURFACES IAW DC8 SRM 51-1-11. INSTALLED NEW PANEL PLATING IAW SRM 51-1-21.